Infusion pump

$
0
0

Infusion pump Model SK-600I

Maximum size of outer shell: 120x140x190mm. Maximum weight: <2.5 kg. Power supply: AC 220V; 50/60Hz. Displayed information: infusion rate;presetting infusion volume accumulated infusion volume; battery capacity; battery charge indicator ; AC power indicator ; infusion over ; occlusion alarm; air bubble in tube; bed number. Accumulated infusion quantity display: 1~9999ml. Infusion precision: ±5%. KVO rate: 1ml/h. Alarm function: OVER.; occlusion; low battery power; installation error; air bubble; liquid exhaustion; machine malfunction. Electrical safety: In according with the stipulation of GB9706.1-199.5. Electromagnetic wave protection: In according with the stipulation of IEC60601-1-2 (1993 edition). Fuse: 220V2A ×2/ 12V 2A ×2. Infusion increment: 1ml/h. Maximum power consumption: 25VA running more than two hours after being charged. Applicable infusion sets: All standard transparent infusion sets. Infusion rate range: 1-600ml/h. Feasible preset infusion volume: 1~9999ml. Fast infusion volume: 1.0ml. Fast infusion speed: 600ml/h. Battery: Rechargeable lithium battery 7.4V 16500mAh.

Infusion pump Model SK-600 IB

Bolus: 600ml/h. Flow rate range: 1-2000ml/h. Volume limit: 1-9999 ml. Accuracy: ±5%. KVO flow rate: 1ml/h, keep vein open(KVO) rate. Power supply: AC100-240V, 50/60 Hz,25VA. Max. power consumation:  25W can run for more than 5 hours continously after fully recharged. Battery recharge: When the pump is working and connected to the AC power,the battery will automatically recharge (about 8-14 hours to recharge fully.)  Displayed information: Flow rate,volume limit,accumulated volume,power indicator, bed. No air, occlusion, empty. Alarm function: Infusion completion,occlusion,air bubble,low battery,control abnormal,no AC power supply,installation error. Max. size of outer shell: 120×140×190 mm. Max. weight: 2.5 kg. Classification: Type IIB. Outer shell material:  ABS plastic. Operating condition: Environment temperature +5°- +40° atmosphere presure 86-106kPa  related humidity 20%-90%. Applicable infusion pipe: All standard infusion pipes. Work mode: Continuous work mode.  Applicable standard: Comply with standard of EN ISO 14971:2000, IEC 60601-1:1995, EN IEC 60601-1-2:2001, IEC 60601-2-24, EN ISO 14155-1:2003, EN 980:2003, EN 1041:1998, MDD 93/42 EEC.

Syringe pump SK-500I

Maximum size of outer shell: 288x130x122mm. Syringe increment: 0.1ml/h. Maximum weight: <3.0 kg. Fast syringe quantity: 1.0ml. Power supply: AC 220V/50/60Hz. Fast syringe speed: 10ml syringe:100ml/h; 20ml syringe: 200ml/h 50ml syringe: 500ml/h. Displayed information: syringe speed; Accumulated syringe; syringe specification quantity; battery capacity; battery charge indicator; AC power indicator; bed number. Alarm function: completion; syringe near completion; occlusion; low battery; syringe abnormal ; control abnormal; machine malfunction. Electric safety: In according with the stipulation of GB9706.1-199.5; EN60601-1 andUL60601-1. Fuse: 220V2A ×2/ 12V 2A ×2. Syringe precision: ±3%. Maximum power consumption: 25VA; running more than five hours after being charged. Accumulated syringe quantity: 0.1~999.9ml. Applicable injectors: Syringes meeting national standard: 10ml; 20ml and 50ml. Environment condition: environment temperature 5~45°; pressure 70~106kPa; relative humidity 30%~90%. Electromagnetic wave protection: 10ml in according with the stipulation of IEC60601-1-2 (1993 Edition). Feasible syringe speed range: 10ml syringe0.1~100ml/h; 20ml syringe 0.1~200ml/h; 50ml syringe 0.1~500ml/h. Battery: Rechargeable lithium battery: 7.4V 1650mAh

Syringe Pum SK-500II

Dimesion: 288×130×122mm. Weight: 3.0kg. Power supply: 50/60Hz AC100V~240V. Display information: Flow rate, accumulated syringe volume, Preset volume, Syringe size, Pressure value, Syringe specification, Battery capacity, Unit of medical dosage, AC power indicator, Bed number, Pressure Value. Fuse: 220V 2A ×2  12V2A×2. Max power consume: 25VA  5h after being recharged. Syringe increment: 0.1ml. Accumulated injection volume: 0~9999.9ml. Syringe accuracy: ±3%. Alarm function (can be transmitted to the infusion supervision system at the nures station): End of infusion, Near end of infusioin, Occlusion, Low battery, Disengaged, Injector abnormal, Control abnormal, Internal malfunction. Electrical safety: Complies with the stipulation of GB9706.1-199.5 EN60601-1 and UL60601-1. Electromagnetic compatibility: Complies with the stipulation of IEC60601-1-2 (1993 edition). Applicable syringe: Syringes meeting national standared: 5ml;10ml;20ml;30ml;50ml. Feasible syringe rate range: 5ml syringe: 0.1~100ml/h; 10ml syringe: 0.1~200ml/h; 20ml syringe : 0.1~400ml/h; 30ml syringe: 0.1~600ml/h; 50ml syringe: 0.1~1500ml/h. Battery: Rechargeable lithium polyer battery; 7.4V; 1600mA. Bolus rate: 5ml: 100ml/h; 10ml: 200ml/h; 20ml: 400ml/h; 30ml: 600ml/h; 50ml: 1500ml/h. Ocllusion value: 400mmHg~900mmHg. Selectable mode: Flow rate mode, Time mode, Weight mode. Time mode: Liquid limit: 0.1~999.9ml Time:0~2000mins. Weight mode: Selectable unit:ml/h; mg/h; ug/h; mg/kg/h; mg/kg/min; ug/kg/h; ug/kg/min. Medical limt: 0.1~9999.9 (mg/ug). Liquid limit: 0.1~999.9ml. Weight: 01~300.0kg. KVO rate: 0.1ml/h~5.0ml/h. Environment condition: Environment temperature 5~45°C air pressure 70~106kPa  relative humidity 30%~90%.

Product Name SK-2000I Infusion Supervision

Type of product: SK-2000I. Maximum size of outer shell: 500x600x600mm(Lx W x H). Applicable infusion pipe: Infusion pipes and syringes meeting the national standard. Maximum weight: 7.0kg. Maximum power consumption: 500VA. Classification: TypeII equipment(lightning-proof). Monitor Type: Infusion pump ; Syinge pump. Monitor number: 4sets to 50sets. Precision: ±5% after prior setup and adjustment of the pump. Shell material: ABS plastic (fire-proof). Power requirement: 50Hz AC85-265V. Workingenvironment: environment temperature 5~40℃, pressure 70~106kPa  relative humidity30%~80%. Fuse: two batteries of 220V 0.5A one battery of 120V 0.5A. Progress date refresh: <2 seconds. Electric safety: according with the stipulation of GB97006.1-1995.

 

 

 

Infusion pump JAS-1200

Pumping type: Peristaltic finger pump. IV set: Standard IV set (15,20 drops/ml),or micro IV set (60drops/ml) with 3.4-3.5mm tubing. Flow rate: 0.1-1200ml/h or 1-400d/min. Accuracy: ±2%,≤25d/min(300ml/h); ±5%,>25d/min(300ml/h). Preset total infusion volume: 1-9999ml. Occulusive Sensitivity: Adjustable. KVO rate: Flow≤10ml/h,KVO is 1ml/h; Flow>10ml/h,KVO is 3ml/h. Alarm: Infusion Monitoring:  Air in tube, door open, occlusion, pause, infusion complete, abnormal drips, leakage, tube slope etc. Diagnosis malfunctions:  Low battery, damage battery, abnormal drip detector, abnormal peristaltic finger pump. Occlusion limited pressure: High,middle and low. Alarm sound: High, middle and low. Work Condition: 5~40,relative humidity≤90%. Purge: >600ml/h. Display: LCD. Power supply: AC90V-230V±10% 50Hz/60Hz; Li-battery,DC11V 2000mAh. Power consumption: ≤20W. Battery Life: The battery can be used approcimately 10 hours,if it is fully charged after charging 6 hours. Net weight: About 2kg. Pump dimension: 130x120x30MM. Classification: Class II; Internal power supply; type CF; Portable ; IPX4. Applied range: Venous infusion, Vascular expansion solution, Anticancer rugs, Accelerative procreate drugs, Nutrient liquid and all of liquid medicine, mini infusions and rapid infusions.

 

 

 

Infusion pump JAS-XB

Pumping type: Peristaltic finger pump. IV set: Standard IV set (15,20 drops/ml),or micro IV set (60drops/ml) with 3.4-3.5mm tubing. Flow rate: 1-1000ml/h. Accuracy: Dedicated line: ±5%; Standard line: ±8%. Preset total infusion volume: 1-9999ml. Occulusive Sensitivity: Adjustable. KVO rate: 1ml/h. Alarm: Infusion Monitoring:  Air in tube, door open, occlusion, pause, infusion complete, abnormal drips, leakage, tube slope etc. Diagnosis malfunctions:  Low battery, damage battery, abnormal drip detector, abnormal peristaltic finger pump. Work Condition: Circumstance Temperature: 10-35º, infusion precision will decrease when temperature ≤18º;Humidity:30~93%. Purge: 600ml/h. Display: LED. Power supply: AC:80V-240V; Battery: 10*AA size NIMH. Power consumption: ≤20W. Battery Life: When battery fully charged,pump can continuously work about 3 hours at an infusion rate of 100ml. Net weight: About 2.1kg. Pump dimension: 176x128x225MM. Classification: Class II; Internal power supply; type CF; Portable ; IPX4. Applied range: Venous infusion, Vascular expansion solution, Anticancer rugs, Accelerative procreate drugs, Nutrient liquid and all of liquid medicine, mini infusions and rapid infusions.

 


 

 